Approval Details

Valid E.O.

Validity

This Executive Order approved the specified parts on on October 27, 2005.
As of Thursday, December 26th, 2024 this Executive Order has not been overturned or superceeded.

Approved Parts

ModelsModification
2001-2005 model-year 3.4 liter GM Venture minivans, originally equipped with a 25 gallon mid-ship tankThe stock tank can be replaced with a 20 gallon aft-axle tank.

This Executive Order may be listed as:
  • C.A.R.B.E.O. D-288-54
  • Executive Order 288-54 / D288-54
  • ARB # D-288-54
  • Executive Order No: D-288-54
  • C.A.R.B. No. D-288-54
  • Resolution D-288-54
For Free CARB Executive Order Status verification, email an image of the device Executive Order label as well as the Year/Make/Model and Test Group # of the vehicle to [email protected]

Download: Executive Order D-288-54 PDF

D-288-54 Document:


CARB_D-288-54

                                    State of California
                                AIR RESOURCES BOARD

                              EXECUTIVE ORDER D—288—54

                                Relating to Exemptions under
                             Section 27156 of the Vehicle Code

                                    Transfer Flow, Inc.
                               Replacement Fuel Storage System

Pursuant to the authority vested in the Air Resources Board by Section 27156 of the Vehicle
Code; and

Pursuant to the authority vested in the undersigned by Sections 39515 and 39516 of the Health
and Safety Code and Executive Order G—02—003;

IT IS ORDERED AND RESOLVED: That installation of the Replacement Fuel Storage System,
manufactured by Transfer Flow, Inc. (TF!) of 1444 Fortress Street, Chico, California 95973, has
been found not to reduce the effectiveness of the applicable vehicle pollution control system,
and therefore, the Replacement Fuel Storage System is exempt from the prohibitions in Section
27156 of the Vehicle Code for installation on the following vehicles:

Model—Year      Vehicle Model              Engine Size      Stock Tank          TFI Tank

2001—2005       GM Venture minivans        3.4 liter        25 gal. mid—ship    20 gal. aft—axle
2005            GM Uplander minivans 3.5 liter              25 gal. mid—ship    20 gal. aft—axle
2006            GM Uplander minivans 3.5 & 3.9 liter        25 gal. mid—ship    20 gal. aft—axle

This Executive Order is based on an engineering evaluation of the impact on emissions and
testing TF! conducted with similar Replacement Fuel Storage Systems. it is concluded that
the Replacement Fuel Storage System would not adversely affect the vehicles‘ emissions or
reduce the effectiveness of their On—Board Diagnostics !I Systems.

Exemption of the Replacement Fuel Storage System shall not be construed as an exemption to
sell, offer for sale, or advertise any component of the Replacement Fuel Storage System as
individual devices.

This Executive Order shall not apply to any device advertised, offered for sale, sold with, or
installed on a motor vehicle prior to or concurrent with transfer to an ultimate purchaser.

This Executive Order is valid provided that installation instructions for the Replacement Fuel
Storage System do not recommend tuning the vehicle to specifications different from those
of the vehicle manufacturer.

 Changes made to the design or operating conditions of the Replacement Fuel Storage
 System, as exempt by the Air Resources Board, which adversely affect the performance of
 the vehicle‘s pollution control system shall invalidate this Executive Order.

 Marketing of the Replacement Fuel Storage System using an identification other than that
 shown in this Executive Order or for an application other than those listed in this Executive
 Order shall be prohibited unless prior approval is obtained from the Air Resources Board.


                                                  «2.

     In addition to the foregoing, the Air Resources Board reserves the right in the future to
     review this Executive Order and the exemption provided herein to assure that the exempted
     add—on or modified part continues to meet the standards and procedures of Title 13,
     California Code of Regulations, Section 2222 et seq.

     This Executive Order does not constitute any opinion as to the effect the use of the
     Replacement Fuel Storage System may have on any warranty either expressed or implied
     by the vehicle manufacturer.

     No claim of any kind, such as "Approved by the Air Resources Board," may be made with
     respect to the action taken herein in any advertising or other oral or written communication.

     THIS EXECUTIVE ORDER DOES NOT CONSTITUTE A CERTIFICATION,
     ACCREDITATION, APPROVAL, OR ANY OTHER TYPE OF ENDORSEMENT BY THE
     AIR RESOURCES BOARD OF CLAIMS OF THE APPLICANT CONCERNING
     ANTI—POLLUTION BENEFITS OR ANY ALLEGED BENEFITS OF TRANSFER
     FLOW, INC.‘S REPLACEMENT FUEL STORAGE SYSTEM.

     Violation of any of the above conditions shall be grounds for revocation of this Executive
     Order. The Executive Order may be revoked only after a ten—day written notice of intention
     to revoke the Executive Order, in which period the holder of the Executive Order may
     request in writing a hearing to contest the proposed revocation. If a hearing is requested, it
C)




     shall be held within ten days of receipt of the request and the Executive Order may not be
     revoked until a determination is made after the hearing that grounds for revocation exist.

     Executed at El Monte, California, this Z7 “5       day of October 2005.




                                          Alle     ns, Chief
                                          Mobile Source Operations Division




          TRANSFER FLOW, INC. — REPLACEMENT FUEL STORAGE SYSTEM — D—288—54



Document Created: 2005-11-23 09:06:15
Document Modified: 2005-11-23 09:06:15

Previous E.O. D-288-53 | Previous E.O. D-287 | Next E.O. D-288-55 | Next E.O. D-289