Approval Details

Valid E.O.

Validity

This Executive Order approved the specified parts on on June 25, 2014.
As of Monday, October 21st, 2024 this Executive Order has not been overturned or superceeded.

Approved Parts

Part NumberModelsModification
OSS761920-2014 model year passenger cars to medium-duty trucks equipped with gasoline or diesel engines up to 4.0 liters.Braided vinyl hose is inserted into the opening of the air intake housing.

This Executive Order may be listed as:
  • C.A.R.B.E.O. D-732
  • Executive Order 732 / D732
  • ARB # D-732
  • Executive Order No: D-732
  • C.A.R.B. No. D-732
  • Resolution D-732
For Free CARB Executive Order Status verification, email an image of the device Executive Order label as well as the Year/Make/Model and Test Group # of the vehicle to [email protected]

Download: Executive Order D-732 PDF

D-732 Document:


CARB_D-732

                                     State of California
                                 AIR RESOURCES BOARD

                                 EXECUTIVE ORDER D-732

                               Relating to Exemptions unoer
                             Section 27156 of the Vehicle Code

                                  Central Valley HHO, Inc.
                                 Hydrogen Generator Device

Pursuant to the authority vested in the Air Resources Board by Section 27156 of the
Vehicle Code; and

 Pursuant to the authority vested in the undersigned by Sections 39515 and 39516 of the
 Health and Safety Code and Executive Order G-14-012;

 IT IS ORDERED AND RESOLVED: That installation of the hydrogen generator device,
 manufactured by Central Valley HHO, Inc. (1320 Standiford Avenue #4 PMB 316,
 Modesto, California 95350), has been found not to reduce the effectiveness of the
 applicable vehicle pollution control.systems, and therefore, the OSS76, OS136, and
 OSS78 hydrogen generator devices are exempt from the prohibitions in Section 27156
 of the Vehicle Code for all 1920-2014 model year passenger cars, light-duty trucks, and
 medium-duty trucks with gasoline or diesel engines up to 8 liters.

·The OSS76, OS136, and OSS78 hydrogen generator devices consists of a 2, 3, or 4
 quart water reservoir, a single cell electrolysis generator, a controller, various electrical
 components, electrical wiring and connectors, an electrolyte, and clear braided vinyl
 supply hose for the hydrogen gas.

 This Executive Order is based on emission test results using Cold-Start CVS-75 Federal
 Test Procedure test, Supplemental Federal Test Procedure test, and On-Board
 Diagnostic II System test submitted by Central Valley HHO, Inc. with the hydrogen
 generator device. installed.

 If evidence provides the Air Resources Board with reasons to suspect that the hydrogen
 generator device will affect the durability of the emission control system, Central Valley
 HHO, Inc. shall be required to submit durability data to show that the durability of the
 vehicle emission control system is not, in fact, affected and/or that the add-on or
 modified parts demonstrate adequate durability.

 This Executive Order is valid provided that installation instructions for the hydrogen
 generator device do not recommend tuning the vehiCles to specifications different from
 those of the vehicle manufacturer.                         ·

 Changes made to the design or operating conditions of the hydrogen generator device,
 as exempt by the Air Resources Board, which adversely affect the performance of the
 vehicle's emission control system, shall invalidate this Executive Order.


                                               9.

Marketing of the hydrogen generator device using identification other than that shown in
this Executive Order or for an application other than that listed in this Executive Order
shall be prohibited unless prior approval is obtained from the Air Resources Board.

Exemption of the hydrogen generator device shall not be construed as exemption to
sell, offer for sale, or advertise any component of the kit as an individual device.

This Executive Order shall not apply to any hydrogen generator device advertised,
offered for sale, sold with, or installed on a motor vehicle prior to or concurrent with
transfer to an ultimate purchaser.

This Executive Order does not constitute any opinion as to the effect the use of the
hydrogen generator device may have on any warranty either expressed or implied by
the vehicle manufacturer.     '

No claim of any kind, such as "Approved by the Air Resources Board," may be made
with respect to the action taken herein in any advertising or other oral or written
communication.

In addition to the foregoing, the Air Resources Board reserves the right in the future to
review this Executive Order and the exemption provided herein to assure that the
exempted add—on or modified part continues to meet the standards and procedures of
California Code of Regulations, Title 13, Section 2222, et seq.

THIS EXECUTIVE ORDER DOES NOT CONSTITUTE A CERTIFICATION,
ACCREDITATION, APPROVAL, OR ANY OTHER TYPE OF ENDORSEMENT BY THE
AIR RESOURCES BOARD OF ANY CLAIMS OF THE APPLICANT CONCERNING
ANTI—POLLUTION BENEFITS OR ANY ALLEGED BENEFITS OF CENTRAL VALLEY
HHO, INC.‘S HYDROGEN GENERATOR DEVICE.

Violation of any of the above conditions shall be grounds for revocation of this Executive
Order. The Executive Order may be revoked only after a ten day written notice of
intention to revoke the Executive Order, in which period the holder of the Executive
Order may request in writing a hearing to contest the proposed revocation. If a hearing
is requested, it shall be held within ten days of receipt of the request, and the Executive
Order may not be revoked until a determination is made after the hearing that grounds
for revocation exist.               |                    .
                                         x )hs
Executed at El Monte, California, this 575/    day of June 2014.


                    —      |      MM\-Q,/
                 nnetteé       Hebert, Chief        .
                 missions Compliance, Automotive Regulations and Science Division




            CENTRAL VALLEY HHO, INC. —HYDROGEN GENERATOR DEVICE — D—732


                                     EVALUATION SUMMARY

 Manufacturer Name: Central Valley HHO, Inc.

 Name of Device: .OSS76, OS136, and OSS78 Hydrogen Generator Device

 Background:
        Central Valley HHO, Inc. of 1320 Standiford Avenue #4 PMB 316, Modesto, California
 95350 has applied for exemption from the prohibitions in Section 27156 of the California Vehicle
·Code for its hydrogen generator device. The device is designed for use on 1920-2014 model ·
 year (MY) passenger cars, light-duty trucks, and medium-duty trucks with gasoline or diesel
 engines up to 8.0 liters.

 Recommendation:
        Grant exemption to Central Valley HHO, Inc. as requested and issue Executive Order
 D-732.                               .

 Device Description:
         The hydrogen generator device produces hydrogen through an electrolysis process by
 supplying water from a reservoir containing distilled water and an activator (sodium hydroxide or
 potassium hydroxide) to an electrolysis dry cell containing stainless steel plates that are
 supplied electricity from the vehicle's battery. The device consists of a 2, 3, or 4 quart water
 reservoir, a single cell electrolysis generator (which contain the positive, negative, and neutral
 metal plates), a controller, various electrical components, e·lectrical wiring and connectors, and
 clear braided vinyl supply hose for the hydrogen gas. The device is connected to the vehicle's
 fuel pump relay circuit so that hydrogen gas is only produced when the engine is operating.

 Discussion/Basis for the Recommendation:
        This exemption is based on: FTP, SFTP, and OBD II System tests conducted on a
 2013 MY 2.0 liter Ford Fusion LEV II ULEV and also FTP and OBD II System tests conducted
 on a 2011 MY 6.7 liter Ford F-350 diesel medium-duty truck LEV II ULEV. Testing was
 conducted on these vehicles and modified with the hydrogen generator device to evaluate the
 impact on emissions. Results are shown below:                                               ·

 FTP. SFTP. and OBD II System tests on a 2013 MY 2.0 liter Ford Fusion

                                   FTP Emissions (grams/mile)
                           NMOG        co          NOx
       Test Results        0.026        1.1        0.02
   Test Results w/50K DF   0.026        1.2        0.02
      50K Standards        0.040        1.7        0.05
         Pass/Fail         Pass        Pass        Pass


  Test Results w/120K DF   0.026        1.4        0.03
      120K Standards       0.055        2.1        0.07
         Pass/Fail         Pass        Pass        Pass


                                                                       . SFTP Emissions (grams/mile)
                                                                        NMHC+NOx            co
       Test Results                                                '        0.09            2.2
       4K Standards                                                         0.14            8.0
         Pass/Fail                                                          Pass           Pass


                                                                  OBD II System Results

                                                      Readiness Indicator           Trouble Code   MIL

            At vehicle receipt                           All complete                     None     Off
                                                All complete except evaporative
           After 50 mile drive                                                            None     Off
                                                            system
  After hydrogen generator device FTP
                                                         All complete                     None     Off
             and SFTP tests



FTP and OBD II System tests on a 2011 MY 6.7 liter Ford F-350 diesel medium-duty truck

                                         FTP Emissions (grams/mile)
                                 NMOG        co          NOx            PM
      Test Results               0.031        0.5         0.2           0.01
. Test Results w/120K OF         0.066        0.7         0.2           0.01
     120K Standards              0.167        7.3         0.4           0.06
        Pass/Fail                Pass        Pass        Pass           Pass


                                                                  OBD II System Results

                                                     Readiness Indicator            Trouble Code   MIL

           At vehicle receipt                            All complete                     None     Off
                                              All complete except fuel system and
           After 50 mile drive                                                            None     Off
                                                      exhaust Qas sensor
  After hydrogen generator device FTP
                                                All complete except fuel system           None     Off
                  test

Notes: 1. The fuel system monitor was not able to set to complete on the 2011 Ford F-350 because the
       vehicle's powertrain control module had not yet been reprogramed, based on Ford Motor
       Company's Technical Service Bulletin 12-8-21. Staff feels that the emission test results are well
       below the emission standards and that this incomplete monitor will not affect the test results.
       2. Deterioration factors (OF) are additive.
       3. Testing laboratory for all above tests- Automotive Testing and Development Services, Inc. in
       Ontario, California.


FTP and SFTP exhaust emission results for the 2013 Ford Fusion and 2011 Ford F-350 showed
that the modified vehicles meet the exhaust emission standards. Testing also showed that the
modification does not have any adverse impact on the vehicle's 080 II System. Similar results
are expected when Central Valley HHO, lnc.'s· hydrogen generator device is used on the
1920-2014 model year passenger cars, light-duty trucks, and medium-duty trucks with gasoline
or diesel engines up to 8 liters stated in this application.



Document Created: 2014-07-01 15:11:24
Document Modified: 2014-07-01 15:11:24

| Previous E.O. D-731 | Next E.O. D-732-1 | Next E.O. D-733